Model EE210 Temp
Choice of 7 Moisture Values

Applications

  • Utilization of dew point and temperature to control economizer not to exceed indoor design conditions.
  • One high quality, weather station quality sensor can be used to control all air intakes on a building or within a number of blocks.
  • In many cases temperature or enthalpy control will introduce moisture levels well over the indoor design dew point that actually will require additional dehumidification by the air conditioning system when activated.
  • For more information see the AirTest Economizer Guide on the right side of this web page.
  • AirTest can provide transmitters that calculate dew point (EE23, EE07) or transmitters that provide accurate humidity and temperature readings that can be used with the correct psychometric calculations to determine dew point.

 

Key Features

  • All sensor use highly stable E+E sensing elements that have excellent long-term stability and are maintenance free.
  • Radiation shields available with all transmitters that protect the sensor from the effects of sunlight heating, wind effects, snow effects or rain effects.
  • A special environmental coating of the sensor is available, as an option will protect the humidity sensor against salt air and air pollution.
  • Probe devices allow for easy replacement if necessary.
  • EE071 provides a MODbus RTU output.

EE210 Transmitter For Outdoor & Harsh Environments With Choice of 7 Moisture Output Measurements

The EE210 will be replacing the EE21 and is designed to operate in outdoor or harsh environments and includes a specially coated sensing element that protects the sensor from normally destructive chemicals such as salt air, ammonia and chlorine. Other features of this product include:

  • Available with or without display.
  • Duct or Wall Mounting.
  • Outputs available: 0-5V, 0-10V, 4-20 mA, Modbus (soon).
  • Dual analog outputs that can include outputs for: Temperature, Relative Humidity, Dew Point, Frost Point, Mixing Ratio, Absolute Humidity, Specific Enthalpy (all values available via Modbus).
  • Supports one or two point calibration.
  • Operating Range: 0-100% RH, -40 to 140F (-40 to 60C).
  • Accuracy:
    • -15...40°C (5...104°F) ≤90% RH (1.3 + 0.3%*mv) % RH
    • -15...40°C (5...104F) >90% RH 2.3% RH
    • -40...60°C (0...140F) (1.5 + 1.5%*mv) % RH
  • 24VAC Power
  • Compatible with the AirTest the affordable RM1000 radiation shield.

Datasheet
Manual
Radiation Shield

 

 
 

RM1000 Outdoor Radiation Shield With OA Probes

AirTest, Weather Station Quality, RM1000 Radiation Shield With EE Voltage Output or Modbus Output Probes

This product is intended to provide a durable but cost effective method of measuring outside temperature and moisture conditions. It combines the AirTest RM1000 radiation shield that is designed to accommodate a variety of 12 mm diameter probes with two probe options that offer analog outputs for temperature and humidity (EE060) or Modbus EE071) outputs for temperature and 5 different moisture measurement parameters (including dew point). The probes are easily inserted into the compression fitting in the shield and the screw on cable connector to the probes allows for easy installation and replacement. Further details on these probes are provided below.


Datasheet

 

 
 

EE060 Humidity & Temperature Probe

EE060 Humidity & Temperature Probe with Voltage Output

A humidity and temperature probe with special environmental coating that protects the sensor element from pollutants and salt air. Available with screw-on or connected cable. Can be used with the AirTest RM1000 radiation probe.

  • Extremely cost effective.
  • Excellent long term stability.
  • Outputs: provides 0-10V outputs for temp and % RH.
  • Accuracy: RH 2.5%, Temp 0.5F (0.3C) Dew point can be calculated with and external controller which should provide 1.4F Td (0.7C Td)

Datasheet
Manual
Radiation Shield

 

 
 

Model EE23 Analog Output

EE23C Analog Dew Point and Temperature Transmitter With Remote Probe

  • A weather station quality transmitter designed for measurement of outside air, that utilizes a remote probe and recommended optional weather shield (PN: HA010502).
  • Provides a direct dew point output, can also calculate various other psychometric values.
  • Measurement Range: 0-100% RH; -40...120 C and dew points within this range.
  • Accuracy: +/-1.3% RH; +/-0.2 C
  • Two analog output with user selectable output options: 0-5V, 0-10V, 0-20mA, 4-20mA
  • Power: 24 VAC/VDC

EE23 Datasheet and Order Guide
EE23 Manual

 

 
 

Radiation Shield for Outside Air Monitoring

EE071 Modbus RTU (RS485) Probe with Dew Point And Temperature Output

  • Stand alone probe with integrated calibration and built in psychometric calculations for dew point and other moisture variables.
  • Suitable for outside air monitoring with recommended optional radiation shield (PN: HA010502)
  • Sensor is configurable via a PC interface with connecting cable (PN:HA011001).
  • Sensor is coated for environmental protection against salt air, pollution and other harsh chemicals.
  • Measurement Range: 0...100% RF, -40...80C
  • Output: digital Modbus RTU
  • Accuracy: 2%RH (0...90%RH), 3%RH (90...100%RH); Temp 0,2C at 20C
  • Power: 4...18 VDC

EE071 Datasheet
EE071 Modbus Application Note
EE071 Configuration Software

 

 
 

Radiation Shield for Outside Air Monitoring

EE07 Temperature And Humidity Probe With Serial (E2) Output

  • Stand alone probe with integrated calibration. Measures Temperature and humidity.
  • Suitable for outside air monitoring with recommended optional radiation shield (PN: HA010502)
  • Sensor is configurable via a PC interface with connecting cable (PN:HA011001).
  • Sensor is coated for environmental protection against salt air, pollution and other harsh chemicals.
  • Measurement Range: 0...100% RF, -40...80C
  • Output: serial output using the E2 protocol
  • Accuracy: 2%RH (0...90%RH), 3%RH (90...100%RH); Temp 0,2C at 20C
  • Power: 4...18 VDC

EE07 Datasheet
E2 Interface to the EE07
E2 Communication Protocol Specifications
Application note on using the E2 Serial Interface

 

 
 

Radiation Shield for Outside Air Monitoring

EE08 Temperature And Humidity Probe With Serial And Analog Output

  • Stand alone probe with integrated calibration. Measures Temperature and humidity.
  • Suitable for outside air monitoring with recommended optional screw-in radiation shield (PN: HA010506)
  • Measurement Range: 0-100% RH; -40...80C
  • Accuracy: +/- 2% RH; +/- 0.2 C
  • Power: 4.5 - 15VDC or 7 - 30VDC
  • Output: 2-wire digital output (E2) and analogue output 0-1/2,5/5/10V

EE08 Datasheet
EE08 Manual
Using the E2 Interface with the EE08
EE08 Radiation Shield Manual
E2 Communication Protocol Specifications
Application note on using the E2 Serial Interface

 

 