Model TR0200
Oxygen (O2)

Applications

  • Measurement of Oxygen Depletion.
  • Ideal where temperatures, pressures and humidity fluctuate.
  • Ideal for cold environments down to
    -40 F/C.

 

Key Features

  • No maintenance Zirconium cell
  • No calibration required
  • No drift due to environmental or temperature changes
  • Operates at -40C in freezers
  • 10 + years sensor life
  • Local display, 4-20mA output
  • Joystick adjustable dual alarm relays
  • Integral computer controlled electronics
  • CE approved EMC EN 61326-1:2006
  • Made in the USA

TR0200 Long Life, Self Calibrating
Oxygen Transmitter

  • Sampling Method & Range: Diffusion, 0-25%
  • Operating Temperatures: -40 to 131F (-40 to 55C)
  • Sensor Type: long life Zirconium Oxide Sensor Cell
  • Sensor Life: 10+ years under normal operating conditions
  • Output: 4-20 mA, optional: dual relays, audible alarm
  • Power: 24VDC 100 mA without relays, 500 mA with relays
  • Calibration Requirement: None

Datasheet
 
Published: May 22, 2013 Last Updated: May 22, 2013